Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
1.
Graefes Arch Clin Exp Ophthalmol ; 262(5): 1607-1618, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38183466

RESUMO

PURPOSE: Estimating glaucoma suspects' risk for visual field defects helps to avoid under- and over-treatment. In this retrospective, longitudinal cohort study with a very long follow-up, we studied whether pattern electroretinograms (PERG) amplitudes and blue-on-yellow visual evoked potential (BY-VEP) latencies can predict visual field defects. METHODS: Participants of the Erlangen Glaucoma Study were examined with PERG and BY-VEP between 9/1991 and 8/2001. Stimuli were created using an optical bench with Maxwellian view and consisted of vertical gratings (0,88 cpd) in a 32° field for both PERG and BY-VEP. Patients were treated according to clinical standards and performed standard automated perimetry (SAP) annually. Retrospectively, patients with normal SAP at baseline were selected. Primary endpoint was conversion to perimetric glaucoma. Predictive value was modeled using Kaplan-Meier analyses and a multivariate cox proportional hazards model with the continuous variables PERG amplitude, BY-VEP peak time and SAP square-root of loss variance (sLV) after stratification for Jonas classification of the optic discs. RESULTS: Of 412 patients (288: Jonas 0, 103: I, and 21: II; baseline age: 20-60 years), 65 converted to perimetric glaucoma during follow-up (0.5-23.3 years; median 5.5 years). Optic disc classification was a strong risk factor for conversion (log rank p < 0.0001), and patients with more advanced changes progressed earlier. In the multivariate analysis (log rank p = 0.005), only PERG amplitude remained an independent risk factor after stratification for optic disc morphology (p = 0.021), with a ~ 30% higher risk per µV amplitude decrease. CONCLUSIONS: PERG helps to estimate glaucoma suspects' risk for visual field defects.


Assuntos
Glaucoma , Hipertensão Ocular , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Testes de Campo Visual , Potenciais Evocados Visuais , Estudos Retrospectivos , Campos Visuais , Seguimentos , Estudos Longitudinais , Pressão Intraocular , Hipertensão Ocular/tratamento farmacológico , Glaucoma/diagnóstico , Eletrorretinografia , Transtornos da Visão/diagnóstico
2.
Doc Ophthalmol ; 148(1): 15-24, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37749441

RESUMO

PURPOSE: To correlate multifrequency pattern reversal VEPs in quadrants (QmfrVEPs) with perimetric field losses for objective detection of visual field losses. METHODS: QmfrVEP measurements were performed using four LED-based checkerboard stimulators to stimulate the four quadrants of the visual field. QmfrVEPs were measured monocularly in 5 normal subjects and in 5 glaucoma patients who showed losses in conventional Octopus perimetry. The pattern reversal frequency varied slightly between the stimulators: (11.92, 12.00, 12.08 and 12.16 reversals/sec). The responses to the different stimuli were identified by discrete Fourier analysis. VEPs were recorded using different electrode configurations, and the recording with the highest signal-to-noise ratio (SNR) was used for further analysis. RESULTS: QmfrVEP responses from the different quadrants can be reliably measured and separated using the 0.08 reversals/sec interstimulus reversal frequency differences. The signal-to-noise ratio in the four quadrants was significantly correlated with the equivalent visual field losses obtained with perimetry (Spearman rank correlation: P < 0.001). In the five glaucoma patients, the SNR was reduced in 15 out of the 16 quadrants with a perimetric defect, in comparison to the results in quadrants of healthy subjects. This confirms the sensitivity of the procedure. CONCLUSION: QmfrVEP responses can be measured reliably. This pilot study suggests that high SNR values exclude visual field defects and that focal defects can be identified in glaucoma patients. TRIAL REGISTRATION: www. CLINICALTRIALS: gov . NCT00494923.


Assuntos
Glaucoma , Testes de Campo Visual , Humanos , Testes de Campo Visual/métodos , Campos Visuais , Projetos Piloto , Eletrorretinografia , Transtornos da Visão/diagnóstico , Glaucoma/diagnóstico , Potenciais Evocados Visuais
3.
PLoS One ; 18(5): e0284743, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37146019

RESUMO

The paper presents a comparative study of the pulsatile attenuation amplitude (PAA) within the optic nerve head (ONH) at four different areas calculated from retinal video sequences and its relevance to the retinal nerve fiber layer thickness (RNFL) changes in normal subjects and patients with different stages of glaucoma. The proposed methodology utilizes processing of retinal video sequences acquired by a novel video ophthalmoscope. The PAA parameter measures the amplitude of heartbeat-modulated light attenuation in retinal tissue. Correlation analysis between PAA and RNFL is performed in vessel-free locations of the peripapillary region with the proposed evaluating patterns: 360° circular area, temporal semi-circle, nasal semi-circle. For comparison, the full ONH area is also included. Various positions and sizes of evaluating patterns in peripapillary region were tested which resulted in different outputs of correlation analysis. The results show significant correlation between PAA and RNFL thickness calculated in proposed areas. The highest correlation coefficient Rtemp = 0.557 (p<0.001) reflects the highest PAA-RNFL correspondence in the temporal semi-circular area, compared to the lowest value in the nasal semi-circular area (Rnasal = 0.332, p<0.001). Furthermore, the results indicate the most relevant approach to calculate PAA from the acquired video sequences is using a thin annulus near the ONH center. Finally, the paper shows the proposed photoplethysmographic principle based on innovative video ophthalmoscope can be used to analyze changes in retinal perfusion in peripapillary area and can be potentially used to assess progression of the RNFL deterioration.


Assuntos
Glaucoma , Disco Óptico , Humanos , Fibras Nervosas , Células Ganglionares da Retina , Glaucoma/diagnóstico , Tomografia de Coerência Óptica/métodos
4.
J Glaucoma ; 32(3): 186-194, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36730078

RESUMO

PRCIS: COVID-19 underlines the importance of telemedical diagnostics. The smartphone-based campimetry (Sb-C) is a newly developed digital application allowing visual field testing using a head-mounted device and a smartphone. It enables visual field screening remotely from a clinic. BACKGROUND: Sb-C is a newly developed tool for functional ophthalmic diagnosis. This study aimed to examine the comparability of the Sb-C and Octopus 900 to ensure ophthalmological care in times of social distancing. METHODS: Total 93 eyes were included in the study. After an ophthalmological examination, the visual field was tested by the Octopus program G1 and by the smartphone-based campimeter. The Sb-C was performed using VR glasses and an iPhone 6. The software Sb-C was downloaded and installed as SmartCampiTracker app and is examining the 30-degree visual field with 59 test positions corresponding to the G pattern of Octopus G1. Sensitivities were recorded and saved on the app. In addition, test-retest reliability was tested on 6 ophthalmologically healthy participants. RESULTS: The group comprised 48 women and 45 men (mean age: 62.52±12.2 y) including 19 controls, 17 patients with ocular hypertension, 11 preperimetric glaucomas, and 46 perimetric glaucomas. The mean sensitivity (MS) of all points of G1 perimetry was 23.13 dB (95% CI, 22.08-24.18). The MS of the Sb-C was 21.23 dB (95% CI, 20.37-22.08). The correlation between the mean MS measured by G1 perimetry and the Sb-C was strong ( r =0.815, P <0.05). The test-retest reliability showed a correlation of r =0.591 ( P <0.05) . CONCLUSIONS: With some technical adjustments, the Sb-C shows promise for screening glaucoma and monitoring disease progression remotely from an ophthalmologic clinic.


Assuntos
COVID-19 , Glaucoma , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Campos Visuais , Smartphone , Reprodutibilidade dos Testes , Pressão Intraocular , Glaucoma/diagnóstico , Testes de Campo Visual
5.
Graefes Arch Clin Exp Ophthalmol ; 260(4): 1171-1181, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34821990

RESUMO

BACKGROUND AND AIM: In the past, increased latencies of the blue-on-yellow pattern visually evoked potentials (BY-VEP), which predominantly originate in the koniocellular pathway, have proven to be a sensitive biomarker for early glaucoma. However, a complex experimental setup based on an optical bench was necessary to obtain these measurements because computer screens lack sufficient temporal, spatial, spectral, and luminance resolution. Here, we evaluated the diagnostic value of a novel setup based on a commercially available video projector. METHODS: BY-VEPs were recorded in 126 participants (42 healthy control participants, 12 patients with ocular hypertension, 17 with "preperimetric" glaucoma, and 55 with perimetric glaucoma). Stimuli were created with a video projector (DLP technology) by rear projection of a blue checkerboard pattern (460 nm) for 200 ms (onset) superimposed on a bright yellow background (574 nm), followed by an offset interval where only the background was active. Thus, predominantly S-cones were stimulated while L- and M-cone responses were suppressed by light adaptation. Times of stimulus onset to VEP onset-trough (N-peak time) and offset-peak (P-peak time) were analyzed after age-correction based on linear regression in the normal participants. RESULTS: The resulting BY-VEPs were quite similar to those obtained in the past with the optical bench: pattern-onset generated a negative deflection of the VEP, whereas the offset-response was dominated by a positive component. N-peak times were significantly increased in glaucoma patients (preperimetric 136.1 ± 10 ms, p < 0.05; perimetric 153.1 ± 17.8 ms, p < 0.001) compared with normal participants (123.6 ± 7.7 ms). Furthermore, they were significantly correlated with disease severity as determined by visual field losses retinal nerve fiber thinning (Spearman R = -0.7, p < 0.001). CONCLUSIONS: Video projectors can be used to create optical stimuli with high temporal and spatial resolution, thus potentially enabling sophisticated electrophysiological measurements in clinical practice. BY-VEPs based on such a projector had a high diagnostic value for detection of early glaucoma. Registration of study Registration site: www. CLINICALTRIALS: gov Trial registration number: NCT00494923.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Hipertensão Ocular , Potenciais Evocados Visuais , Glaucoma/diagnóstico , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Testes de Campo Visual
6.
Invest Ophthalmol Vis Sci ; 62(9): 14, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34241626

RESUMO

Purpose: To compare the electroretinographical (ERG) responses elicited by L- and M-cone isolating ON- and OFF-sawtooth stimuli in normal subjects and glaucoma patients. Methods: Twenty-one normal subjects and 44 primary open-angle glaucoma patients participated in the study. L- and M-cone isolating (18% cone contrast; 284 cd/m2) rapid ON- and rapid OFF-sawtooth (4 Hz) stimuli with two stimulus sizes (full-field (FF) and central 70° diameter) were generated using the triple silent substitution technique. ON- and OFF-response asymmetries were studied by adding the two (to obtain L-add and M-add responses). The initial positive (P) and subsequent late negative (LN) components of the L-add and M-add ERGs were compared between the subject groups and correlated with retinal nerve fiber layer thickness (RNFLT) and pattern ERG responses. Results: The responses to L-ON and to M-OFF stimuli and vice versa resembled each other particularly with 70° stimuli. The PL-add amplitudes were not significantly different between the normal subjects and glaucoma patients, whereas the LNL-add amplitude was significantly (P < 0.01) smaller in the glaucoma patients. Both PM-add and LNM-add were not significantly different between the subject groups. The PERG amplitude with 0.8° check sizes and the 0.8°/16° amplitude ratio (PERG ratio) were significantly (P < 0.05) different between the subject groups. The 70° LNL-add amplitude and the 0.8° PERG amplitude were significantly correlated with RNFLT. Conclusions: The ERGs to 70° cone isolating sawtooth stimuli reflect cone opponency. The cone opponent ERG responses were not significantly different between glaucoma patients and normal subjects. Luminance driven L-add responses were significantly different, indicating that central luminance signals are mainly affected in glaucoma.


Assuntos
Eletrorretinografia/métodos , Glaucoma de Ângulo Aberto/fisiopatologia , Retina/fisiopatologia , Células Fotorreceptoras Retinianas Cones/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa/métodos
7.
PLoS One ; 16(5): e0249202, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33961631

RESUMO

PURPOSE: Agonistic ß2-adrenergic receptor autoantibodies (ß2-agAAb) have been observed in sera of patients with ocular hypertension and open-angle glaucoma (OAG). They target the ß2-receptors on trabecular meshwork, ciliary body and pericytes (Junemann et al. 2018; Hohberger et al. 2019). In addition to their influence on the intraocular pressure, an association to retinal microcirculation is discussed. This study aimed to investigate foveal avascular zone (FAZ) characteristics by en face OCT angiography (OCT-A) in glaucoma suspects and its relationship to ß2-agAAb status in patients with OAG. MATERIAL AND METHODS: Thirty-four patients (28 OAG, 6 glaucoma suspects) underwent standardized, clinical examination including sensory testing as white-on-white perimetry (Octopus G1, mean defect, MD) and structural measures as retinal nerve fibre layer (RNFL) thickness, neuroretinal rim width (BMO-MRW), retinal ganglion cell layer (RGCL) thickness, and inner nuclear layer (INL) thickness with high-resolution OCT. FAZ characteristics were measured by OCT-A scans of superficial vascular plexus (SVP), intermediate capillary plexus (ICP), and deep capillary plexus (DCP). FAZ-R was calculated (area FAZ (SVP)/area FAZ (ICP)). Using cardiomyocyte bioassays we analysed serum samples for the presence of ß2-agAAb. RESULTS: (I) Total mean FAZ area [mm2]: 0.34±0.16 (SVP), 0.24±0.12 (ICP), and 0.49±0.24 (DCP); mean FAZ-R 1.58±0.94. No correlation was seen for FAZ-R with MD, RNFL, BMO-MRW, RGCL thickness and INL thickness (p>0.05). (II) ß2-agAAb have been observed in 91% patients and showed no correlation with MD, RNFL, BMO-MRW, RGCL thickness and INL thickness (p>0.05). (III) FAZ-R correlated significantly with the ß2-agAAb-induced increase of the beat rate of cardiomyocyte (p = 0.028). CONCLUSION: FAZ characteristics did not correlate with any glaucoma associated functional and morphometric follow-up parameter in the present cohort. However, level of ß2-agAAb showed a significantly correlation with FAZ-ratio. We conclude that ß2-agAAb might be a novel biomarker in glaucoma pathogenesis showing association to FAZ-ratio with OCT-A.


Assuntos
Autoanticorpos/imunologia , Glaucoma de Ângulo Aberto/fisiopatologia , Microcirculação/imunologia , Receptores Adrenérgicos beta 2/imunologia , Idoso , Feminino , Glaucoma de Ângulo Aberto/imunologia , Glaucoma de Ângulo Aberto/patologia , Humanos , Pressão Intraocular , Masculino , Células Ganglionares da Retina/patologia
8.
Invest Ophthalmol Vis Sci ; 62(6): 17, 2021 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-33988692

RESUMO

Purpose: The purpose of this study was to characterize summation of temporal L- and M-cone contrasts in the parvo- (P-) and magnocellular (M-) pathways in glaucoma and the relationship between the respective temporal contrast sensitivities (tCS) and clinical parameters. Methods: Perifoveal tCS to isolated or combined L- and M-cone contrasts (with different contrast ratios, and therefore different luminance and chromatic components) were measured at different temporal frequencies (at 1 or 2 Hz and at 20 Hz) using triple silent substitution in 73 subjects (13 healthy, 25 with glaucoma, and 35 with perimetric glaucoma). A vector summation model was used to analyze whether perception was driven by the P-pathway, the M-pathway, or both. Using this model, L- and M-cone input strengths (AL, AM) and phase differences between L- and M-cone inputs were estimated. Results: Perception was always mediated by the P-pathway at low frequencies, as indicated by a median phase angle of 179.84 degrees (cone opponency) and a median AL/AM ratio of 1.04 (balanced L- and M-cone input strengths). In contrast, perception was exclusively mediated by the M-pathway at higher frequencies (input strength not balanced: AL/AM = 2.94, median phase angles = 130.17 degrees). Differences in phase were not significant between diagnosis groups (Kruskal-Wallis = 0.092 for P- and 0.35 for M-pathway). We found differences between groups only for the M-pathway (L-cone tCS deviations at 20 Hz were significantly lower in the patients with glaucoma P = 0.014, with a strong tendency in M-cones P = 0.049). L-cone driven tCS deviations at 20 Hz were linearly correlated with perimetric mean defect (MD) and quadratically correlated with retinal nerve fiber layer (RNFL) thickness. Conclusions: Unaltered phase angles between L- and M-cone inputs in glaucoma indicated intact temporal processing. Only in the M-pathway, contrast sensitivity deviations were closely related to diagnosis group, MD, and RNFL thickness, indicating M-pathway involvement.


Assuntos
Opsinas dos Cones/fisiologia , Sensibilidades de Contraste/fisiologia , Corpos Geniculados/fisiologia , Glaucoma de Ângulo Aberto/fisiopatologia , Células Fotorreceptoras Retinianas Cones/fisiologia , Células Ganglionares da Retina/fisiologia , Adulto , Idoso , Feminino , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica , Testes de Campo Visual , Campos Visuais/fisiologia , Vias Visuais/fisiologia
9.
Graefes Arch Clin Exp Ophthalmol ; 259(2): 483-494, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32960321

RESUMO

PURPOSE: To measure parameters of the cardiac cycle-induced pulsatile light absorption signal (plethysmography signal) of the optic nerve head (ONH) and to compare parameters between normal subjects and patients with different stages of glaucoma. PATIENTS AND METHODS: A recently developed video ophthalmoscope was used to acquire short video sequences (10 s) of the ONH. After image registration and trend correction, the pulsatile changing light absorption at the ONH tissue (excluding large vessels) was calculated. The changing light absorption depends on the pulsatile changing blood volume. Various parameters, including peak amplitude, steepness, time-to-peak, full width at half maximum (FWHM), and pulse duration, were calculated for averaged individual pulses (heartbeats) of the plethysmography signal. This method was applied to 19 healthy control subjects and 91 subjects with ocular hypertension, as well as different stages of primary open-angle glaucoma (17 subjects with ocular hypertension, 24 with preperimetric glaucoma, and 50 with perimetric glaucoma). RESULTS: Compared to the normal subjects, significant reductions (p < 0.001) in peak amplitude and steepness were observed in the group of perimetric glaucoma patients, but no significant difference was found for time-to-peak, FWHM, and pulse duration. Peak amplitude and steepness showed high correlations with RNFL thickness (p < 0.001). CONCLUSIONS: The presented low-cost video-ophthalmoscope permits measurement of the plethysmographic signal of the ONH tissue and calculation of different blood flow-related parameters. The reduced values of the amplitude and steepness parameters in perimetric glaucoma patients suggest decreased ONH perfusion and blood volume. This outcome is in agreement with results from other studies using OCT angiography and laser speckle flowgraphy, which confirm reduced capillary density in these patients. Registration site: www.clinicaltrials.gov , Trial registration number: NCT00494923.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Disco Óptico , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Pletismografia , Tomografia de Coerência Óptica , Campos Visuais
10.
Front Immunol ; 10: 2112, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31632387

RESUMO

Recently, agonistic autoantibodies (agAAb) activating the ß2-adrenergic receptor were detected in primary open-angle glaucoma (POAG) or ocular hypertension (OHT) patients and were linked to intraocular pressure (IOP) (1). The aim of the present study was to quantify ß2-agAAb in the sera of glaucoma suspects and patients with primary and secondary glaucoma. Patients with OHT (n = 33), pre-perimetric POAG (pre-POAG; n = 11), POAG (n = 28), and 11 secondary OAG (SOAG) underwent ophthalmological examinations including examinations with Octopus G1 perimetry and morphometry. Twenty-five healthy individuals served as controls. Serum-derived IgG samples were analyzed for ß2-agAAb using a functional bioassay. The beat-rate-increase of spontaneously beating cultured neonatal rat cardiomyocytes was monitored with 1.6 beats/15 s as cut-off. None of the sera of normal subjects showed ß2-agAAb. In POAG or OHT patients increased beating rates of 4.1 ± 2.2 beats/15 s, and 3.7 ± 2.8 beats/15 s were detected (p > 0.05). Glaucoma patients with (POAG) and without perimetric (pre-POAG) defects did not differ (pre-POAG 4.4 ± 2.6 beats/15 s, POAG 4.1 ± 2.0 beats/15 s, p > 0.05). Patients with SOAG yielded mean beating rates of 4.7 ± 1.7 beats/15 s (p > 0.05). ß2-agAAb were seen in 73% of OHT, 82% of pre-POAG, 82% of POAG, and 91% SOAG patients (p < 0.001). Clinical data did not correlate with beating rate (p > 0.05). The robust ß2-agAAb seropositivity in patients with OHT, pre-POAG, POAG, and SOAG suggest a primary common role for ß2-agAAb starting early in glaucoma pathophysiology and turned out to be a novel marker identifying all patients with increased IOP independent of glaucoma stage and entity.


Assuntos
Autoanticorpos/imunologia , Glaucoma/etiologia , Glaucoma/metabolismo , Receptores Adrenérgicos beta 2/metabolismo , Idoso , Afinidade de Anticorpos/imunologia , Feminino , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Miócitos Cardíacos/metabolismo
11.
Transl Vis Sci Technol ; 8(1): 24, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30834172

RESUMO

PURPOSE: It has been shown that multifrequency stimulation with multifocal electroretinography can reduce recording time without a loss in signal-to-noise ratio. Here, we studied the applicability of multifrequency stimulations for steady-state visually evoked potential (VEP) recordings. METHODS: Multifrequency VEPs were recorded monocularly from 10 healthy subjects using pattern-reversal stimuli. The reversal frequency varied between 5 and 30 Hz. Pattern-reversal checkerboard stimuli were generated using four square arrays, each containing 100 light-emitting diodes (LEDs), positioned in four quadrants. Each array had a temporal frequency that differed slightly from the nominal frequency. The long duration of the data acquisition ensured that the slightly different stimulus frequencies in the four LED arrays can be resolved and that the responses to the stimulus in each array can be distinguished (e.g., with a frequency resolution: 0.011 Hz at 12 Hz). The best response from the four recording electrode configuration, defined as the recording with the maximal signal-to-noise ratio, was used for further analysis. Algorithmic latencies were calculated from the ratio of phase data and frequencies in a range of 4 and 20 Hz. RESULTS: Quadrant-VEPs with simultaneous pattern-reversal stimulation yielded a significant dependency on temporal frequency and stimulus location. The frequency range leading to the maximal response amplitude was between 10 and 12 Hz. Response phases decreased approximately linearly, with increasing temporal frequency suggesting a mean algorithmic latency between 112 and 126 ms. CONCLUSIONS: Multifrequency stimulation using LED arrays is an efficient method for recording pattern-reversal VEPs while all stimuli are presented at the same time. TRANSLATIONAL RELEVANCE: Simultaneously recorded VEPs as performed by the multi-frequency method can be used for objective measurements of visual field defects.

12.
Front Immunol ; 9: 145, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29483909

RESUMO

Glaucoma is a frequent ocular disease that may lead to blindness. Primary open-angle glaucoma (POAG) and ocular hypertension (OHT) are common diseases with increased intraocular pressure (IOP), which are mainly responsible for these disorders. Their pathogenesis is widely unknown. We screened the sera of patients with POAG and OHT for the prevalence of autoantibodies (AAb) against G protein-coupled receptors (GPCRs) in comparison to controls. Employing frequency modulation of spontaneously contracting neonatal rat cardiomyocytes in vitro, agonistic GPCR AAb were to be detected in roughly 75% of the patients with POAG and OHT, however, not in controls. Using inhibitory peptides the AAb' target was identified as ß2 adrenergic receptor (ß2AR). The AAb interact with the second extracellular loop of ß2AR. The peptides 181-187 and 186-192 were identified as binding sites of the AAb within the extracellular loop II. The binding of the AAb to ß2ARs was verified by surface-plasmon-resonance analysis. The isotype of the AAb was (immunoglobulin) IgG3. In an additional pilot principal-of-proof study, including four patients with POAG, the removal of the AAb against the ß2AR and other immunoglobulins G by immunoadsorption resulted in a transient reduction of IOP. These findings might indicate a possible role of agonistic AAb directed against ß2ARs in the dynamics of aqueous humor and might support a contribution of adaptive autoimmunity in the etiopathogenesis of POAG and OHT.


Assuntos
Autoanticorpos/imunologia , Glaucoma de Ângulo Aberto/imunologia , Imunoglobulina G/imunologia , Receptores Adrenérgicos beta 2/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Animais Recém-Nascidos , Sítios de Ligação , Células Cultivadas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miócitos Cardíacos/imunologia , Hipertensão Ocular/imunologia , Ratos Sprague-Dawley , Adulto Jovem
13.
J Glaucoma ; 27(2): 157-163, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29194206

RESUMO

PURPOSE: The purpose of this study was to compare the ability of scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (SD-OCT) to predict future visual field conversion of subjects with ocular hypertension and early glaucoma. METHODS: All patients were recruited from the Erlangen glaucoma registry and examined using standard automated perimetry, 24-hour intraocular pressure profile, and optic disc photography. Peripapillary retinal nerve fiber layer thickness (RNFL) measurements were obtained by SLP (GDx-VCC) and SD-OCT (Spectralis OCT). Positive and negative predictive values (PPV, NPV) were calculated for morphologic parameters of SLP and SD-OCT. Kaplan-Meier survival curves were plotted and log-rank tests were performed to compare the survival distributions. Contingency tables and Venn-diagrams were calculated to compare the predictive ability. RESULTS: The study included 207 patients-75 with ocular hypertension, 85 with early glaucoma, and 47 controls. Median follow-up was 4.5 years. A total of 29 patients (14.0%) developed visual field conversion during follow-up. SLP temporal-inferior RNFL [0.667; 95% confidence interval (CI), 0.281-0.935] and SD-OCT temporal-inferior RNFL (0.571; 95% CI, 0.317-0.802) achieved the highest PPV; nerve fiber indicator (0.923; 95% CI, 0.876-0.957) and SD-OCT mean (0.898; 95% CI, 0.847-0.937) achieved the highest NPV of all investigated parameters. The Kaplan-Meier curves confirmed significantly higher survival for subjects within normal limits of measurements of both devices (P<0.001). Venn diagrams tested with McNemar test statistics showed no significant difference for PPV (P=0.219) or NPV (P=0.678). CONCLUSIONS: Both GDx-VCC and SD-OCT demonstrate comparable results in predicting future visual field conversion if taking typical scans for GDx-VCC. In addition, the likelihood ratios suggest that GDx-VCC's nerve fiber indicator<30 may be the most useful parameter to confirm future nonconversion. (http://www.ClinicalTrials.gov number, NTC00494923; Erlangen Glaucoma Registry).


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Polarimetria de Varredura a Laser/métodos , Tomografia de Coerência Óptica/métodos , Transtornos da Visão/diagnóstico , Campos Visuais/fisiologia , Idoso , Reações Falso-Positivas , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Hipertensão Ocular/diagnóstico , Hipertensão Ocular/fisiopatologia , Valor Preditivo dos Testes , Células Ganglionares da Retina/patologia , Estudos Retrospectivos , Tonometria Ocular , Transtornos da Visão/fisiopatologia , Testes de Campo Visual
14.
J Glaucoma ; 26(4): 373-382, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28118204

RESUMO

PURPOSE: The aim of this study was to compare the predictive value of retinal nerve fiber layer thickness (RNFLT) measurements obtained by optical coherence tomography (OCT), morphometric parameters of confocal scanning laser ophthalmoscopy (CSLO), and frequency-doubling technique perimetry to predict visual field conversion of normal individuals, ocular hypertensive subjects, and early preperimetric glaucoma patients as determined by standard automated perimetry (SAP). PATIENTS AND METHODS: This longitudinal single-center study included 107 eyes of 56 controls, 164 eyes of 98 patients with ocular hypertension, and 169 eyes of 110 patients with preperimetric glaucoma. At baseline, all patients and controls underwent OCT (Spectralis OCT), CSLO (Heidelberg Retina Tomograph) examination, optic disc photography, and frequency-doubling technique perimetry. At baseline SAP was normal in all participants. Univariate and multivariate hazard ratios (HRs) were measured to model the conversion-free survival including morphometric functional and clinical variables. RESULTS: The median follow-up period was 6.9 years. In total, 48 eyes (10.9%) demonstrated visual field conversion in the follow-up. RNFLT temporal-inferior outside normal limits demonstrated the highest HR with 1.2 (95% confidence interval, 1.1-1.4) per 10 µm loss for OCT, and Glaucoma probability score global outside normal limits demonstrated the highest HR with 1.3 (95 % confidence interval, 1.1-1.5) per 0.1 increase for CSLO in a multivariate model adjusted for photograph-based glaucoma staging, central corneal thickness, and SAP pattern SD. CONCLUSIONS: Both measurement of RNFLT by OCT and Glaucoma probability score by CSLO are highly predictive of future visual field conversion and provide independent predictive information beyond optic disc assessment, central corneal thickness, and SAP pattern SD.


Assuntos
Glaucoma/diagnóstico , Pressão Intraocular/fisiologia , Fibras Nervosas/patologia , Oftalmoscopia/métodos , Retina/patologia , Testes de Campo Visual/métodos , Campos Visuais/fisiologia , Adulto , Idoso , Estudos de Casos e Controles , Progressão da Doença , Feminino , Glaucoma/fisiopatologia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/diagnóstico , Hipertensão Ocular/fisiopatologia , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia de Coerência Óptica/métodos
15.
Methods Inf Med ; 55(6): 557-563, 2016 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-27868133

RESUMO

BACKGROUND: Random forests are successful classifier ensemble methods consisting of typically 100 to 1000 classification trees. Ensemble pruning techniques reduce the computational cost, especially the memory demand, of random forests by reducing the number of trees without relevant loss of performance or even with increased performance of the sub-ensemble. The application to the problem of an early detection of glaucoma, a severe eye disease with low prevalence, based on topographical measurements of the eye background faces specific challenges. OBJECTIVES: We examine the performance of ensemble pruning strategies for glaucoma detection in an unbalanced data situation. METHODS: The data set consists of 102 topographical features of the eye background of 254 healthy controls and 55 glaucoma patients. We compare the area under the receiver operating characteristic curve (AUC), and the Brier score on the total data set, in the majority class, and in the minority class of pruned random forest ensembles obtained with strategies based on the prediction accuracy of greedily grown sub-ensembles, the uncertainty weighted accuracy, and the similarity between single trees. To validate the findings and to examine the influence of the prevalence of glaucoma in the data set, we additionally perform a simulation study with lower prevalences of glaucoma. RESULTS: In glaucoma classification all three pruning strategies lead to improved AUC and smaller Brier scores on the total data set with sub-ensembles as small as 30 to 80 trees compared to the classification results obtained with the full ensemble consisting of 1000 trees. In the simulation study, we were able to show that the prevalence of glaucoma is a critical factor and lower prevalence decreases the performance of our pruning strategies. CONCLUSIONS: The memory demand for glaucoma classification in an unbalanced data situation based on random forests could effectively be reduced by the application of pruning strategies without loss of performance in a population with increased risk of glaucoma.


Assuntos
Algoritmos , Bases de Dados como Assunto , Glaucoma/diagnóstico , Área Sob a Curva , Simulação por Computador , Humanos
16.
Graefes Arch Clin Exp Ophthalmol ; 254(5): 937-46, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26883356

RESUMO

PURPOSE: To compare perimetric data based on the second-generation frequency doubling technology (FDT) and on flicker defined form (FDF) stimulation in early glaucoma patients. METHODS: Seventy-two experienced glaucoma patients and 50 healthy subjects of the Erlangen Glaucoma Registry participated in the study. The definition of glaucoma was solely based on optic disc appearance. All patients underwent FDF perimetry (HEP), FDT perimetry (Matrix), standard automated perimetry (SAP, Octopus), and peripapillar measurements of the RNFL thickness (Spectralis OCT). Exclusion criteria were: mean defect (MD) in SAP > 6 dB, eye diseases other than glaucoma, or non-reliable FDF or FDT measurements. Statistical analyses included comparison of the standard indices and correlations between methods. Venn-diagrams show the number of patients with abnormal results in HEP, Matrix, SAP, and mean RNFL thickness. RESULTS: Mean defect data from FDT and FDF perimetry were strongly correlated (R = -0.85, P <0.001). In this cohort of early glaucoma patients, the MD values were 6.1 ± 5.0 dB (FDF) and 4.5 ± 4.1 dB (FDT). Sensitivity in this patient group was 65 % for FDF-MD, 60 % for FDT-MD, and 60 % for RNFL-thickness, all at a specificity of 95 %. The correlation analysis between local RNFL thickness and corresponding visual defects revealed significant Spearman correlation coefficients for the arcuate bundles of the visual field (FDF-inferior: R = -0.65, FDF-superior: R = -0.74, FDT-inferior: R = -0.55, FDT-superior: R = -0.72). CONCLUSION: FDF and FDT stimulations can be used to detect patients with early glaucoma. Combined consideration of RNFL thickness and results from one of these perimetric tests can increase the total number of detected patients.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Baixa Tensão/diagnóstico , Transtornos da Visão/diagnóstico , Testes de Campo Visual/métodos , Campos Visuais , Adulto , Idoso , Estudos de Coortes , Diagnóstico Precoce , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica
17.
Graefes Arch Clin Exp Ophthalmol ; 254(2): 259-68, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26553198

RESUMO

PURPOSE: To investigate whether a conventional, monitor-based multifocal visual evoked potential (mfVEP) system can be used to record steady-state mfVEP (ssmfVEP) in healthy subjects and to study the effects of temporal frequency, electrode configuration and alpha waves. METHODS: Multifocal pattern reversal VEP measurements were performed at 58 dartboard fields using VEP recording equipment. The responses were measured using m-sequences with four pattern reversals per m-step. Temporal frequencies were varied between 6 and 15 Hz. Recordings were obtained from nine normal subjects with a cross-shaped, four-electrode device (two additional channels were derived). Spectral analyses were performed on the responses at all locations. The signal to noise ratio (SNR) was computed for each response using the signal amplitude at the reversal frequency and the noise at the neighbouring frequencies. RESULTS: Most responses in the ssmfVEP were significantly above noise. The SNR was largest for an 8.6-Hz reversal frequency. The individual alpha electroencephalogram (EEG) did not strongly influence the results. The percentage of the records in which each of the 6 channels had the largest SNR was between 10.0 and 25.2 %. CONCLUSION: Our results in normal subjects indicate that reliable mfVEP responses can be achieved by steady-state stimulation using a conventional dartboard stimulator and multi-channel electrode device. The ssmfVEP may be useful for objective visual field assessment as spectrum analysis can be used for automated evaluation of responses. The optimal reversal frequency is 8.6 Hz. Alpha waves have only a minor influence on the analysis. Future studies must include comparisons with conventional mfVEP and psychophysical visual field tests.


Assuntos
Potenciais Evocados Visuais/fisiologia , Campos Visuais/fisiologia , Adulto , Córtex Cerebral/fisiologia , Eletroencefalografia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Razão Sinal-Ruído , Vias Visuais/fisiologia , Adulto Jovem
18.
J Glaucoma ; 25(4): 371-6, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-25304282

RESUMO

PURPOSE: To compare Moorfields regression analysis (MRA), Glaucoma probability score (GPS), and different discriminant functions to predict future visual field conversion of patients with ocular hypertension and early glaucoma. PATIENTS AND METHODS: The study included 120 eyes of patients with ocular hypertension and 110 eyes of patients with early glaucoma from the Erlangen glaucoma registry. Annually, all patients underwent standard automated perimetry, 24-hour intraocular pressure profile, optic disc photography, and HRT (Heidelberg Retina Tomograph I-III; Heidelberg Engineering) measurements. The cohort was divided into 2 groups based on the development of repeatable glaucomatous visual fields. Positive predictive values and negative predictive values were compared for MRA, GPS, and the classification of Bathija, Iester, Mardin, and Mikelberg at baseline. Kaplan-Meier Survival curves and Logrank tests were used to evaluate equality of survival distributions for different test results. RESULTS: Median follow-up was 9.04 years. 26 eyes (11.3%) demonstrated glaucomatous visual field loss in the follow-up. MRA temporal-superior and temporal-inferior outside normal limits were predictive of future visual field loss with positive predictive values of 33.3% and 28.6%. Normal GPS Temporal Sector demonstrated a negative predictive value of 96.4% and normal results in discriminant functions between 94.7% and 95.5%. CONCLUSIONS: Confocal scanning laser tomography is a useful imaging modality to predict future visual field conversion. Development of visual field defects in 10 years is highly unlikely, if GPS classification and/or classification of discriminant analysis at baseline are normal. MRA temporal-superior and temporal-inferior outside normal limits are associated with future VF conversion (ClinicalTrials.gov number, NCT00494923).


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Microscopia Confocal , Disco Óptico/patologia , Doenças do Nervo Óptico/diagnóstico , Transtornos da Visão/diagnóstico , Campos Visuais , Adulto , Diagnóstico Precoce , Reações Falso-Positivas , Feminino , Seguimentos , Gonioscopia , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/diagnóstico , Valor Preditivo dos Testes , Probabilidade , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia , Tonometria Ocular
19.
J Glaucoma ; 25(3): 274-80, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25383467

RESUMO

PURPOSE: To evaluate rates of changes per year of central corneal thickness after antiglaucomatous drug administration with ß-blockers, prostaglandin analogs, and carbonic anhydrase inhibitors monotherapy and combined topical antiglaucomatous therapy, in a cohort of patients with ocular hypertension, glaucoma suspects, and patients with perimetric glaucoma as compared with normal controls. PATIENTS AND METHODS: This retrospective single-center study included 130 eyes as healthy controls, 121 eyes of ocular hypertensive patients, 105 eyes of glaucoma suspects, and 49 eyes of perimetric glaucoma patients. All patients underwent standard automated perimetry, 24-hour intraocular pressure profile, optic disc photography, and optical coherence pachymetry (OCP; Heidelberg Engineering). The cohort was divided into 8 groups on the basis of topical antiglaucomatous medication. Linear regression analysis was conducted to analyze the relationship between central corneal thickness and exposure to antiglaucomatous medication during the follow-up. RESULTS: Central corneal thickness did not change during the follow-up for investigated diagnostic subgroups. There was a statistically significant decrease in central corneal thickness for eyes treated with prostaglandin monotherapy (-3.1 µm/y for left eye), and a combined therapy with prostaglandins, carbonic anhydrase inhibitors, and ß-blockers (-5.8 and -3.8 µm/y for right and left eye, respectively). CONCLUSIONS: We recommend regular measurements before and during therapy with prostaglandin monotherapy and a combined therapy with prostaglandins, carbonic anhydrase inhibitors, and ß-blockers. Follow-up intraocular pressure measurements may be underestimated for eyes treated with the aforementioned treatment regimens if central corneal thickness is not measured on a regular basis.


Assuntos
Anti-Hipertensivos/efeitos adversos , Córnea/efeitos dos fármacos , Doenças da Córnea/induzido quimicamente , Glaucoma de Ângulo Aberto/tratamento farmacológico , Pressão Intraocular/efeitos dos fármacos , Antagonistas Adrenérgicos beta/administração & dosagem , Antagonistas Adrenérgicos beta/efeitos adversos , Adulto , Idoso , Anti-Hipertensivos/administração & dosagem , Inibidores da Anidrase Carbônica/administração & dosagem , Inibidores da Anidrase Carbônica/efeitos adversos , Córnea/fisiopatologia , Doenças da Córnea/fisiopatologia , Paquimetria Corneana , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Interferometria , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/tratamento farmacológico , Hipertensão Ocular/fisiopatologia , Prostaglandinas F Sintéticas/administração & dosagem , Prostaglandinas F Sintéticas/efeitos adversos , Estudos Retrospectivos , Tonometria Ocular , Testes de Campo Visual
20.
JAMA Ophthalmol ; 133(10): 1135-43, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26225533

RESUMO

IMPORTANCE: New methods are needed to compare peripapillary retinal nerve fiber layer thickness (pRNFLT) measurements taken from time-domain optical coherence tomography (TD-OCT) and spectral-domain OCT (SD-OCT). OBJECTIVE: To compare the agreement of measured and predicted pRNFLT using different equations based on pRNFLT measurements obtained by TD-OCT and SD-OCT. DESIGN, SETTING, AND PARTICIPANTS: Cross-sectional single-center study that took place at the Department of Ophthalmology, University of Erlangen-Nuremberg from November 16, 2005, to June 3, 2015, and included 138 eyes of control participants, 126 eyes of patients with ocular hypertension, 128 eyes of patients with preperimetric glaucoma, and 160 eyes of patients with perimetric glaucoma. All participants had standard clinical examinations to obtain TD-OCT (via Stratus OCT) and SD-OCT (via Spectralis OCT) measurements of pRNFLT. Two groups were matched for diagnostic subgroup, eye side, sex, and age. The TD-OCT measurements of the first group were used to predict the mean SD-OCT and 6-sector vertical-split pRNFLT measurements of the second group and vice versa. The agreement between the predicted pRNFLT calculations of conversion equations and measured pRNFLT of the second group was evaluated by intraclass correlation coefficients and Bland-Altman plots. MAIN OUTCOMES AND MEASURES: Mean and sectoral pRNFLT measurements obtained by TD-OCT and SD-OCT as well as the agreement between measured and predicted pRNFLT. RESULTS: The agreement for all investigated equations to predict mean pRNFLT measurements with intraclass correlation coeffecients ranged from 0.937 to 0.939. Bland-Altman plots demonstrated systemic biases between -0.7 µm and +1.1 µm for measured and predicted mean pRNFLT measurements. The ratio method demonstrated an intraclass correlation coefficient of 0.969 for the temporal-inferior sector. The best color-code agreement between both OCT devices was achieved by the no conversion method, with κ = 0.731 (95% CI, 0.656-0.806) for the mean pRNFLT. CONCLUSIONS AND RELEVANCE: These data suggest that the prediction of mean pRNFLT values by equations derived from TD-OCT and SD-OCT can be conducted with high levels of agreement. In individual cases and singular sectors, high prediction errors may occur. When longitudinal imaging data from both TD-OCT and SD-OCT are available, conversion equations may provide longitudinal comparability.


Assuntos
Glaucoma/diagnóstico , Fibras Nervosas/patologia , Disco Óptico/patologia , Doenças do Nervo Óptico/diagnóstico , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Estudos Transversais , Progressão da Doença , Reações Falso-Negativas , Feminino , Gonioscopia , Humanos , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/diagnóstico , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo , Tomografia de Coerência Óptica/instrumentação , Tonometria Ocular , Testes de Campo Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...